Low peak expiratory flow and subsequent first self-report of recognized lung disease: Person-disjoint replication and spirometric benchmarking in HRS and ELSA.
| Year of Publication |
2026
|
|---|---|
| Author | |
| Journal |
PloS one
|
| Volume |
21
|
| Issue |
10
|
| Number of Pages |
e0360668
|
| ISSN Number |
1932-6203
|
| Abstract |
BACKGROUND: Low peak expiratory flow (PEF) may precede the first self-report of recognized lung disease, but cross-cohort consistency and incremental value are uncertain. METHODS: We analysed Health and Retirement Study (HRS) discovery and prespecified person-disjoint replication samples and the English Longitudinal Study of Ageing (ELSA). The estimand linked baseline PEF to the first subsequently observed self-report of recognized lung disease, not biological onset. HRS used a prespecified nominal lower-decile z score and ELSA an empirical lower decile. Participant-clustered models adjusted for demographic, clinical and functional factors. Weighting and a stroke comparator were sensitivity analyses. Post-hoc ELSA benchmarking compared PEF with FEV1 and FVC using person-disjoint cross-validation and full-pipeline bootstrap sensitivity. RESULTS: Models included 18,510 HRS discovery windows (320 reports), 11,424 replication windows (188), and 8,634 ELSA person-waves (95). Low PEF was associated with first report in discovery (odds ratio [OR] 3.36, 95% confidence interval [CI] 2.54-4.45), replication (3.14, 2.19-4.49), and ELSA (3.77, 2.36-6.01). Weighted estimates were similar; stroke associations were weaker or null. After adjustment for separate FEV1 and FVC indices, the continuous-PEF OR was 1.04 (0.90-1.20). In 1,584 fixed-horizon participants (95 events), AUCs were 0.650 for covariates, 0.684 with PEF, 0.745 with FEV1 and FVC, and 0.739 with all three. Full-pipeline bootstrap sensitivity found no clear incremental evidence beyond FEV1 and FVC. Across differing horizons, low-PEF rules identified fewer than one-third of reports in HRS replication and ELSA. CONCLUSIONS: Lower PEF was associated with a subsequent first observed lung-disease report; cohort-specific low-PEF rules identified fewer than one-third. In exploratory fixed out-of-fold predictions, PEF improved average precision and prediction error over covariates; no clear incremental evidence remained after FEV1 and FVC. Same-protocol collection does not establish a peak-flow-only pathway. |
| DOI |
10.1371/journal.pone.0360668
|
| PMID |
42862804
|
| PMCID |
PMC13657285
|
| Download citation |